Compliances:
GJB65 (corresponding to MIL-R-39016)
GJB1042 (corresponding to MIL-R-5757)
GJB1461 (corresponding to MIL-R-6106)
Applications:
low-level, middle current and rated load test for
kinds of non-
latching or latching relays.
Specifications:
|
Model |
ELEB-LH |
ELEB-LL |
ELEB-ML |
ELEB-H |
|
Test temperature |
最高150℃ |
-70℃~150℃ |
常温 |
|
Test capacity |
64位(最多80位) |
64位(最多80位) |
12位 |
|
Drive power |
3V~40VDC程控(可根据需求配置) |
|
Pulse width |
10ms~5000ms(对磁保持型) |
|
Contact load |
开路电压10mV~50mV
程控 |
开路电压3~35VDC程控(可根据需求配置) |
最大电流40A/触点
(最高允许电压60VDC) |
|
闭合电流10mA~50mA |
闭合电流10mA~0.1A |
|
Operation frequency |
1~1800次/分钟 |
0.1~60次/分钟 |
|
Break-make ratio |
1:100~100:1 |
|
Allowable failures |
1~255(可循环记录) |
|
Monitor time |
10%~90% |
|
Disconnection failure criterion |
1mV~50mV |
10mV~5V |
100mV~5V |
|
Adhesion failure criterion |
80%、85%、90%、95% |
|
Working features: |
●
特制横向风道试验箱,插板安装方式(ELEB-LH、ELEB-LL和ELEB-ML);
●
全过程监测负载电源电压、线圈激励脉冲;
●
全过程监测触点压降,自动判断故障类型并记录故障信息,提供4种故障处理方式;
●
监测器件外壳接地保险丝,发生熔断时立即报警;
●
可测量继电器的吸合电压和释放电压; |
 |