LIP Series Li-ion Battery Formation and Grading System

 

   
    Reliability-series

Battery placement classification:

1)  P series=open frame +thimble jig, applicable to cylindrical Li-batteries;

2) B series=chamber + jig board(with jigs), applicable to polymer or soft packing and other soft electrode Li-battery or soft lead paralleled battery pack, HB=high chamber(room temperature+1075℃);

3) C series=open frame + lead or jig, applicable to polymer or soft packing and other soft electrode Li-batteries;

4) F series=automatic neilsbed + battery tray, especially applicable to cylindrical battery’s choice and group-made before application.

Voltage range: Charge range: 0-5000mV; discharge range: 2000-5000mV.

Table of the current and corresponding units:

P series, B series, C series

Charge and discharge current

0.5A / 0.75A

1.5A / 2A / 3A

5A / 6A

10A / 15A

Channel number

512

512

256

128

Accuracy  of voltage and current

±(0.1%FS+0.1%RD)

±(0.05%FS+0.05%RD)

±(0.1%FS+0.2%RD)

±(0.05%FS+0.05%RD)

±(0.1%FS+0.2%RD)

±(0.05%FS+0.05%RD)

±(0.05%FS+0.05%RD)

Charge and discharge current

20A

30A

50A

Channel number

96

64

32

Accuracy  of voltage and current

±(0.05%FS+0.05%RD)

±(0.05%FS+0.05%RD)

±(0.05%FS+0.05%RD)

 

 

 

 

 

 

 

 

 

F series: all of the accuracy of voltage and current is ± (0.05%FS+0.05%RD).

Charge and discharge current

3A

5A

10A

Channel number

96×6 / 96×8 / 256×3 / 150×3

96×4 / 96×6

72×4

Application

1426 series and prismatic

1832 series

32 series

     Battery-series
 
 
 

 